  • 插入式1.png
  • 插入式2.png
  • 插入式5.png
  • 插入式3.png
  • 插入式4.png

Insertion-type electromagnetic flowmeter CLD-8028

Henan Zhongce Sensor Manufacturing Co., Ltd. has launched the CLD-8028 insertion-type electromagnetic flowmeter, designed to meet the flow‑measurement needs of small and medium‑diameter pipelines. It is suitable for applications such as industrial circulating water, cooling water, chilled water systems, water supply branch lines, and general process pipelines. Featuring a stainless‑steel probe and a graduated positioning base, the device delivers precise measurements while offering an economical and practical metering solution for pipe sizes ranging from DN50 to DN400.

Category:

Plug-in electromagnetic flowmeter


Product details


Insertion Electromagnetic Flowmeter CLD-8028

Henan Zhongce Sensor Manufacturing Co., Ltd. has launched the CLD‑8028 insertable electromagnetic flowmeter, designed to meet the flow‑measurement needs of small and medium‑diameter pipelines. It is suitable for applications such as industrial circulating water, cooling water, chilled water systems, water‑supply branch lines, and general process pipelines. Featuring a stainless‑steel probe and a graduated positioning base, the device delivers precise measurements while offering an economical and practical metering solution for pipe sizes ranging from DN50 to DN400.

Stainless steel probe

The probe body is made of stainless steel, offering excellent structural rigidity and strong pressure resistance, enabling it to withstand high‑velocity flow erosion and pressure fluctuations within pipelines. The smooth stainless‑steel surface minimizes scaling under favorable water quality conditions, helping to keep the electrode tip clean and extending maintenance intervals. This material exhibits good compatibility with neutral water, cooling water, and mildly corrosive media.

Applicable caliber range

This model is suitable for pipe diameters ranging from DN50 to DN400, covering small and medium‑size branch lines as well as typical industrial pipelines. Its relatively narrow diameter range, combined with a graduated positioning design, helps ensure accurate insertion depth, thereby delivering more stable measurement results under the corresponding flow conditions.

Convenient installation with a graduated base

The CLD-8028 is equipped with a mounting base marked with scale indicators, allowing users to determine the probe insertion depth directly based on the pipe diameter and the markings on the base during installation—eliminating the need for repeated on-site measurements and calculations. This design streamlines the installation process, reduces reliance on operator experience, and helps minimize measurement errors caused by deviations in insertion depth.

Installation Instructions

This model must be installed after the pipeline has been shut down and depressurized, with all water drained. The installation procedure is as follows: Drill a hole at the designated location on the pipeline, weld the graduated base to the outer wall of the pipe, and once the weld has cooled, insert the probe through the base until it reaches the scale mark corresponding to the pipe’s nominal diameter. Then secure the seal. Please note that this model does not support in‑service, pressurized installation; we recommend completing installation during scheduled shutdowns or during the initial laying of new pipelines.

Measurement accuracy

Provided that the straight‑pipe section requirements are met and the insertion depth is accurate, the CLD‑8028 achieves a measurement accuracy of ±1.5%. For typical applications such as industrial process control, water‑consumption monitoring, and equipment energy‑efficiency assessment, this level of accuracy suffices for most use cases.

Converter Function Configuration

The accompanying converter features a 4–20 mA analog output, a pulse output, and an RS‑485 communication interface, and supports the Modbus protocol.

Installation and Usage Highlights

The installation location should be selected in a straight pipe section with sufficient length, avoiding flow‑disturbing components such as bends and valves. The probe insertion depth must strictly follow the markings on the mounting base to ensure that the electrodes are positioned at a location representative of the average flow velocity across the pipe cross‑section. Welding of the mounting base must be performed by certified welders to guarantee a reliable, leak‑tight weld. During operation, it is recommended to periodically inspect the condition of the seals to ensure long‑term, leak‑free performance.

Henan Zhongce Sensor Manufacturing Co., Ltd. conducts factory calibration and performance testing on every CLD-8028 in‑line electromagnetic flowmeter. Based on the customer’s pipeline parameters and installation conditions, we can provide guidance on insertion depth verification and recommend an appropriate installation plan. For detailed specifications or technical consultation, please contact our Sales and Technical Service team at 19943999277, Mr. Ding.

Selection guide


Video explanation


Material download



Filling Electromagnetic Flowmeter

Dedicated Micro-Sized Electromagnetic Flowmeter for Filling Applications The nominal diameter can be as small as DN8. Accuracy: Class ±0.5% PFA Lining Available Optional Threaded or Clamp Connections


Hygienic Electromagnetic Flowmeter

The sanitary electromagnetic flowmeter is specifically designed for industries with stringent hygiene requirements, such as food, beverage, pharmaceuticals, and bioengineering, and is used for highly accurate measurement of conductive liquid flow rates.


Insertion-type electromagnetic flowmeter

Henan Zhongce Sensor Manufacturing Co., Ltd. has launched the CLD-8028 insertion-type electromagnetic flowmeter, specifically designed for flow measurement in large-diameter pipelines. It is widely applicable in water supply networks, raw water transmission and distribution, circulating water systems, district metering, and hydraulic engineering projects. While ensuring measurement accuracy, this product significantly reduces the overall cost of large‑diameter flowmeters and supports online installation without interrupting water service, offering a convenient solution for pipeline upgrades and the addition of metering points.


Electromagnetic water meter

Designed for the water industry, it integrates low power consumption, long life, and remote transmission capabilities, and supports the integration of smart water management systems.


Pipeline electromagnetic flowmeter

The standard pipeline‑type electromagnetic flowmeter manufactured by Henan Zhongce Sensor Manufacturing Co., Ltd. is designed for measuring the volumetric flow of conductive liquids and is widely used in water supply, wastewater treatment, HVAC systems, agricultural irrigation, and general industrial process control. With its stable performance and excellent versatility, this product meets the measurement requirements of most typical operating conditions.


Slurry-type electromagnetic flowmeter

In slurry, sludge, and mineral pulp transport pipelines across industries such as mining, metallurgy, wastewater treatment, and papermaking, conventional flow meters often fail due to wear, corrosion, and electrode fouling. Henan Zhongce Sensor Manufacturing Co., Ltd. has introduced a slurry‑type electromagnetic flowmeter that, specifically addressing these operating conditions, features enhanced sensor materials and advanced converter technology to deliver a reliable and stable measurement solution.

Online message

Leave the information you want to consult, and we will contact you as soon as possible

Submit