+
  • 66(1784166449015).jpg
  • 插入式1.png
  • 插入式2.png
  • 插入式5.png
  • 插入式3.png
  • 插入式4.png

Insertion-type electromagnetic flowmeter CLD-8028

Henan Zhongce Sensor Manufacturing Co., Ltd. has launched the CLD-8028 insert-type electromagnetic flowmeter, designed to meet the flow‑measurement needs of small and medium‑diameter pipelines. It is suitable for applications such as industrial circulating water, cooling water, chilled water systems, water supply branch lines, and general process pipelines. Featuring a stainless‑steel probe and a graduated positioning base, the device delivers accurate measurements while offering an economical and practical metering solution for pipe sizes ranging from DN50 to DN400.

Category:

Plug-in electromagnetic flowmeter


Product details


Insertion Electromagnetic Flowmeter CLD-8028

Henan Zhongce Sensor Manufacturing Co., Ltd. has launched the CLD-8028 insertion-type electromagnetic flowmeter, designed to meet the flow‑measurement needs of small and medium‑diameter pipelines. It is suitable for applications such as industrial circulating water, cooling water, chilled water systems, water supply branch lines, and general process pipelines. Featuring a stainless‑steel probe and a graduated positioning base, the device delivers precise measurements while offering an economical and practical metering solution for pipe sizes ranging from DN50 to DN400.

Stainless steel probe

The probe body is made of stainless steel, offering excellent structural rigidity and strong pressure resistance, enabling it to withstand high‑velocity flow erosion and pressure fluctuations within pipelines. The smooth stainless‑steel surface minimizes scaling under favorable water quality conditions, helping to keep the electrode tip clean and extending maintenance intervals. This material exhibits good compatibility with neutral water, cooling water, and mildly corrosive media.

Applicable caliber range

This model is suitable for pipe diameters ranging from DN50 to DN400, covering small and medium‑size branch lines as well as typical industrial pipelines. Its relatively narrow diameter range, combined with a graduated positioning design, helps ensure accurate insertion depth, thereby delivering more stable measurement results under the corresponding flow conditions.

Convenient installation with a graduated base

The CLD-8028 is equipped with a mounting base marked with scale indicators, allowing users to determine the probe insertion depth directly based on the pipe diameter and the scale markings on the base, eliminating the need for repeated on-site measurements and calculations. This design streamlines the installation process, reduces the reliance on operator experience, and helps minimize measurement errors caused by deviations in insertion depth.

Installation Instructions

This model must be installed after the pipeline has been shut down and depressurized. The installation procedure is as follows: Drill a hole at the designated location on the pipeline, weld the graduated base to the outer wall of the pipe, and once the weld has cooled, insert the probe through the base until it reaches the scale mark corresponding to the pipe’s diameter. Then secure the seal. Please note that this model does not support in-service, pressurized installation; we recommend completing installation during scheduled shutdowns or during the initial laying of new pipelines.

Measurement accuracy

Provided that the straight‑pipe section requirements are met and the insertion depth is accurate, the CLD‑8028 achieves a measurement accuracy of ±1.5%. For typical applications such as industrial process control, water‑consumption monitoring, and equipment energy‑efficiency assessment, this level of accuracy suffices for most use cases.

Converter Function Configuration

The accompanying converter features a 4–20 mA analog output, a pulse output, and an RS‑485 communication interface, and supports the Modbus protocol.

Installation and Usage Guidelines

The installation location should be selected in a straight pipe section with sufficient length, avoiding flow‑disturbing components such as bends and valves. The probe insertion depth must strictly follow the markings on the mounting base to ensure that the electrodes are positioned at a location representative of the average flow velocity across the pipe cross‑section. Welding of the mounting base must be performed by a certified welder to guarantee a reliable, leak‑tight weld. During operation, it is recommended to periodically inspect the condition of the seals to ensure long‑term, leak‑free performance.

Henan Zhongce Sensor Manufacturing Co., Ltd. performs factory calibration and performance testing on every CLD-8028 in-line electromagnetic flowmeter. Based on the customer’s pipeline parameters and installation conditions, we can provide guidance on insertion depth verification and recommend an appropriate installation plan. For detailed specifications or technical consultation, please contact our sales and technical service team at 19943999277, Mr. Ding.

Selection guide


Video explanation


Material download



Scraper electrode electromagnetic flowmeter

The Zhongce Sensing scraper‑electrode electromagnetic flowmeter centers on manual scraper cleaning, addressing the industry’s longstanding challenge of electrode fouling. Its standardized power supply and liner options meet the demanding requirements of most harsh operating conditions. As an original equipment manufacturer, it delivers robust product reliability while maintaining a competitive price advantage. This solution serves as a practical alternative to conventional electromagnetic flowmeters, enabling long‑term, stable measurement of high‑viscosity and easily adhering media.


High-pressure electromagnetic flowmeter

A high-pressure electromagnetic flowmeter is a precision instrument specifically designed to measure the flow rate of conductive liquids in high-pressure pipelines. Based on Faraday’s law of electromagnetic induction, it accurately determines fluid velocity and flow rate by measuring the induced electromotive force generated as the fluid cuts across magnetic field lines. Thanks to its unique structural design and material selection, it can operate reliably under the demanding high-pressure conditions found in industries such as oil, chemical processing, metallurgy, and hydropower, making it a core device for precise measurement of high-pressure fluids, process control, and energy management.


Filling electromagnetic flowmeter

Micro electromagnetic flowmeter specially designed for filling applications Available with a minimum nominal diameter of DN8 Accuracy class ±0.5% PFA-lined Optional threaded or clamp‑on connections


Hygienic electromagnetic flowmeter

The hygienic electromagnetic flowmeter is specifically designed for industries with stringent hygiene requirements, such as food, beverage, pharmaceutical, and bioengineering, and is used for high-precision measurement of the flow rate of conductive liquids.


Insertion-type electromagnetic flowmeter CLD-6034

Henan Zhongce Sensor Manufacturing Co., Ltd. has launched the CLD‑6034 insertion-type electromagnetic flowmeter, specifically designed for flow measurement in large‑diameter pipelines. It is widely applicable in water supply networks, raw water transmission and distribution, circulating water systems, district metering, and hydraulic engineering projects. While ensuring measurement accuracy, this product significantly reduces the overall cost of large‑diameter flowmeters and supports online installation without interrupting water service, offering a convenient solution for pipeline upgrades and the addition of metering points.


Electromagnetic water meter

Amid the wave of smart water‑management initiatives and refined water‑resource management, electromagnetic water meters are rapidly emerging as the ideal replacement for traditional mechanical meters, thanks to their distinctive advantages: no moving mechanical parts, high measurement accuracy, a wide flow‑range ratio, low pressure loss, robust reliability, and advanced智能化 features. As a flagship of modern water‑metering technology, electromagnetic water meters serve as the cornerstone for building efficient, intelligent, and sustainable water‑supply systems.

Online message

Leave the information you want to consult, and we will contact you as soon as possible

Submit